Sign In | Join Free | My wneducation.com |
|
Brand Name : CHUANQI ELECTRONIC INSTRUMENT
Model Number : CQ series
Place of Origin : China
MOQ : 10pc
Price : Quote according to demand
Payment Terms : L/C, T/T
Supply Ability : 10pcs/month
Delivery Time : 5-8 work days
Measurement : three-phase voltage, current, active power, reactive power, power factor, frequency, active power, reactive power
Display Mode : LCD Display / 12-bit LED Display
Frequency : 45-65Hz
Output : two power pulse output (pulse constant 3200imp/kwh)
Product Name : Three phase multi-function power meter LED
Face Frame Size : 120*120, 96*96, 80*80, 72*72
Communication : RS485 communication, MODBUS-RTU communication protocol
Summarize
Single-phase smart ammeter can measure single-phase current in power grid with high precision, and optional with RS485 communication function and upper and lower limit alarm function. It has the characteristics of easy connection and installation, simple wiring, convenient maintenance, small engineering amount, field programmable setting input parameters, etc., and can complete the network communication of PLC and industrial control computer different from the industry.
PeculiarityMeasurement: single phase current
Display: a row of LED digital tube display, high visibility
Communication: RS485 communication, MODBUS-RTU communication protocol (optional)
Output: Two relay outputs (optional)
Expansion: Input signal can be directly from the current and transformer, and the input parameter ratio can be programmed on site
Application: Suitable for power grid, automatic control system, mainly measure the current parameters in power grid
Product model and size
Model number | CQ42-□I | CQ96-□I | CQ80-□I | CQ72-□I | CQ48-□I | CQ45-□I |
Face frame size | 120*120 | 96*96 | 80*80 | 72*72 | 48*96 | 72*72 |
Opening size | 111*111 | 91*91 | 76*76 | 67*67 | 45*91 | 45*45 |
Technical index
Argument | |||
Accuracy level | Power metering: Active power 0.5, reactive power 1.0, converter output 0.5 | ||
Display mode | LCD display / 12-bit LED display | ||
The signal is entered | Measurement network | Three-phase four-wire V34/ three-phase three-wire V33 | |
Voltage | Rated value | AC380V/AC100V | |
Overload | Duration: 1.2 times instantaneous: 2 times (10 seconds) | ||
Power dissipation | <1VA(per phase) | ||
Impedance | >300kΩ | ||
Electric current | Rated value | AC5A/AC1A | |
Over duty | Duration: 1.2 times instantaneous: 2 times (10 seconds) | ||
Power dissipation | <0.4VA(per phase) | ||
Impedance | < 2 m Ω | ||
Frequency | 45-65Hz | ||
Harmonic wave | Voltage and current total harmonic content and 3-15 odd harmonic components | ||
Electric energy | Bidirectional active and reactive energy metering | ||
Power source | Scope of work | AC/DC85~264V | |
Power dissipation | <5VA | ||
Work and energy modules | Electrical energy pulse | Passive optocoupler output | |
Communication interface | Two RS485 communication ports, Modbus-RTU communication protocol | ||
Communication baud rate: 4800-9600, no parity check N81, E81, or 081 | |||
The second RS485 communication port can be configured as PROFIBUS-DP | |||
Switching input | Passive dry junction input | ||
Switching output | Over limit alarm or remote relay output capacity AC5A/250V,DC5A/30V | ||
Converter output | 0~20mA/4~20mA/0~5V/1~5V converter output, programmable setting of converter items and corresponding output values | ||
Working environment | Ambient temperature: -10~55℃, relative humidity <93%, no corrosive gas place, altitude <2500M | ||
Storage environment | -20~75℃, relative humidity ≤93% | ||
Clock error | < 0.5 s/d | ||
Secure | Insulation | The resistance of signal, power and output terminals to the shell is >100MΩ | |
Withstand voltage | Input voltage >2kV, input and output >1kV, power supply and output >2kV |
![]() |